DTC P1108: Manifold Differential Pressure Sensor - Low Input: Condition
DTC sets when Manifold Differential Pressure (MDP) sensor is higher then specification for 5 continuous seconds. MIL is illuminated when Engine Control Module (ECM) detects malfunction during 2 consecutive drive cycles. Possible causes are:
- MDP sensor malfunction.
- MDP sensor circuit malfunction.
- MDP sensor vacuum passage malfunction.
- ECM malfunction.