DTC C1071/71: Abs Control Module Internal Malfunction
Turn ignition off and disconnect ABS hydraulic unit/control module 34-pin electrical harness connector. Ensure all terminals are free from corrosion, damage and pushed-out pins. Repair as necessary. If harness connector is okay, substitute known-good ABS hydraulic unit/control module assembly and repeat test.