Models Without RKE

  1. Disconnect PDL controller connector. See Fig 1 . Using DVOM, measure voltage at PDL controller connector terminal No. 6 (Blue/Red wire). If reading is 10-14 volts, go to next step. If reading is not 10-14 volts, locate and repair open or short in Blue/Red wire between PDL/RKE connector and DOOR LOCK (15-amp) fuse in junction/fuse block. See Figure . See WIRING DIAGRAMS  . See appropriate wiring diagram in POWER DISTRIBUTION article in WIRING DIAGRAMS.
  2. Check for continuity between ground and PDL controller harness connector terminal No. 1 (Black wire). See Fig 1 . If continuity to ground exists, power supply and ground circuit are okay. If continuity does not exist, repair open Black wire between PDL harness connector and ground. See WIRING DIAGRAMS  . See appropriate wiring diagram in GROUND DISTRIBUTION article in WIRING DIAGRAMS.
    Fig 1: Identifying Power Door Lock Controller Harness Connector Terminals
    G00053777Courtesy of SUZUKI OF AMERICA CORP.