Table D - Air Bag Warning Lamp Cannot Indicate DTC By Flashing
Wiring Diagram:
CAUTION:
- Be sure to perform AIR BAG DIAGNOSTIC SYSTEM CHECK before starting diagnosis according to flow table.
- When measurement of resistance or voltage is required in this table, use a tester along with a correct terminal adapter from special tool (Connector test adapter kit).
- When a check for proper connection is required, refer to INTERMITTENT AND POOR CONNECTIONS.
- If there is open circuit in the air bag wire harness, connector or terminal is found damaged, replace the wire harness, connector and terminal as an assembly.
TABLE TEST DESCRIPTION
STEP 1: Check "AIR BAG" monitor coupler.
STEP 2 : Check diagnosis switch circuit for air bag system.
Step 1 - 2:
Fig. For Step 2:
DIAGNOSTIC FLOW TABLE
NOTE: Upon completion of inspection and repair work, perform following items.
- Reconnect all air bag system components, ensure all components are properly mounted.
- Repeat AIR BAG DIAGNOSTIC SYSTEM CHECK to confirm that the trouble has been corrected.