LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Suzuki >> 2001 >> XL-7 Base, RWD >> Repair and Diagnosis >> Body & Frame >> Power Door Locks & Remote Keyless Entry Systems >> Circuit Tests >> Ignition Switch & Door Switch Circuit
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Ignition Switch & Door Switch Circuit

  1. Disconnect negative battery cable. Disconnect Power Door Lock and Remote Keyless Entry (PDL/RKE) controller harness connector. Connect negative battery cable.
  2. Using DVOM connected to chassis ground, check for voltage at PDL/RKE controller connector terminal No. 4 (Black/White wire). See Figure . With ignition switch in OFF position, DVOM should read about zero volts. With ignition switch in ON position, DVOM should read 10-14 volts. If readings are as described, go to next step. If readings are not as described, repair power supply as necessary. Check for an open or shorted condition in Black/White wire between PDL/RKE controller connector and junction/fuse block IG/METER (20-amp) fuse. See WIRING DIAGRAMS  .
  3. Using DVOM connected to chassis ground, measure resistance at PDL/RKE controller connector terminal No. 10 (Black/Red wire). See Figure . With all doors closed, continuity should not exist. With any door open, continuity should be present. If continuity is as described, ignition switch and door switch circuit test is complete. If readings are not as described, locate and repair open in Black/Red wire between PDL/RKE controller connector terminal No. 10 and buzzer/warning controller at junction/fuse block. See WIRING DIAGRAMS  .