Revised Repair Procedure For A/C Evaporator Freeze-Up During Use (TS 03 03273R)
Publication date: 2003-03-27Reference number: TS 03 03273R
REVISED REPAIR PROCEDURE FOR A/C EVAPORATOR FREEZE-UP DURING USE
TECHNICAL SERVICE BULLETIN
Reference Number(s): TS 03 03273R, Date of Issue:
March 27, 2003
| SUZUKI: | 1999-2002 GRAND VITARA 2001-2002 GRAND VITARA XL-7 |
| SECTION: | HVAC |
CONDITION
A/C stops cooling then begins cooling again after several minutes and/or water dripping from evaporator case on passenger side floor.
CAUSE
A/C evaporator freeze-up during extended use and/or water dripping onto the carpet from condensation building on the outside of the evaporator case.
CORRECTION
Remove A/C evaporator core as outlined in the applicable year and model Service Manual. Remove thermistor probe and move probe above row 7 and clip in row 9 as shown in the following photographs.