DTC P0443: EVAP Circuit, Purge Control Valve Circuit Malfunction: Condition
DTC is set when EVAP canister monitored signal is different from EVAP canister command signal. MIL is illuminated when Power Control Module (PCM) detects malfunction during 2 consecutive drive cycles. Possible causes are:
- EVAP canister purge valve malfunction.