LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Suzuki >> 2001 >> Swift GA L4-1298cc 1.3L SOHC MFI >> Repair and Diagnosis >> Heating and Air Conditioning >> Expansion Valve >> Testing and Inspection >> Inspection
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Inspection




1. Connect manifold gauge set to expansion valve and its charging hose to refrigerant container.
2. Soak remote bulb of expansion valve in water contained in a water pan.
3. Previously close both low and high pressure valves.
4. Open refrigerant container valve.
5. Open high pressure valve to adjust pressure to approx. 5 kg/sq.cm (71 psi).
6. Read the pressure indicated on low pressure gauge. At the same time, use a thermometer to measure water temperature.




7. Use the Chart as shown left to check whether above measurements fall within shaded acceptable range.