LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Suzuki >> 2000 >> Vitara JS, 4D Utility, Automatic >> Repair and Diagnosis >> Transmission >> Automatic Trans >> Automatic Transmission Overhaul - Aw03-72LE & Aw03-73LE >> Performance Tests >> Hydraulic Pressure Tests >> Line Pressure Test
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Line Pressure Test

  1. Ensure engine and transmission are at normal operating temperature. Check fluid level and add if necessary. Connect appropriate pressure gauge to line pressure test port on transmission with a 90 degree fitting to clear exhaust. See Fig 1 .
  2. Connect tachometer. Block all 4 wheels and fully apply parking brake. Start engine and idle.
  3. CAUTION: DO NOT maintain stall speed RPM for more than 5 seconds. Ensure there is at least a one minute pause at idle between tests.
  4. Apply service brake and place selector lever in "D" position. Check line pressure at idle and record pressure reading. Increase RPM to stall speed and record line pressure reading.
  5. Repeat test procedure in "L" and "R" positions. Compare all readings to specification. See HYDRAULIC PRESSURE TEST SPECIFICATIONS  . If line pressures are not as specified, see HYDRAULIC PRESSURE TEST TROUBLE SHOOTING  .
Fig 1: Identifying Transmission Hydraulic Pressure Test Port
G95I21236Courtesy of SUZUKI OF AMERICA CORP.