Oil Pump: Reassembly

  1. Coat NEW oil seal with ATF and install flush with oil pump housing. Place oil pump housing on torque converter. Coat all components with ATF. Align reference marks on driven and drive gears during installation. Align bolt holes and place stator shaft onto pump housing. Install but do not tighten attaching bolts. Install oil pump aligning tool around outside of pump assembly to align pump housing and stator shaft. See Fig 1 .
  2. Tighten oil pump bolts to specification. See TORQUE SPECIFICATIONS  . Remove aligning tool. Install oil sealing rings. DO NOT spread ring ends more than necessary for installation. Ensure sealing rings move smoothly after installation. Ensure oil pump gears rotate smoothly. Lubricate and install "O" ring on oil pump assembly.
Fig 1: Aligning Oil Pump Housing & Stator Shaft
G93E23824Courtesy of TOYOTA MOTOR SALES, U.S.A., INC.