LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Suzuki >> 2000 >> Swift GL L4-1298cc 1.3L SOHC MFI >> Repair and Diagnosis >> Starting and Charging >> Charging System >> Alternator >> Service and Repair >> Dismounting/Remounting
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Dismounting/Remounting

UNIT REPAIR OVERHAUL

DISMOUNTING AND REMOUNTING




1. Disconnect negative cable at battery.
2. Disconnect "B" terminal wire and coupler from generator.
3. Remove generator drive belt adjusting bolt and loosen adjuster arm bolt.
4. Remove generator cover.
5. Remove generator mounting bolts and nut, and then remove generator.
6. To remount, reverse above procedure giving specified tension to drive belt.

Tightening Torque
a: 23 Nm (2.3 kg.m, 17.0 lb.ft)
b: 5.5 Nm (0.55 kg.m, 4.0 lb.ft)
c: 8 Nm (0.8 kg.m, 6.0 lb.ft)