High Pressure Safety Valve HVAC: Service and Repair

High Pressure Relief Valve:




REMOVAL
Remove high pressure relief valve from cylinder head if oil leakage is observed.

INSTALLATION
Install new high pressure relief valve.




1. Coat O-ring of new high pressure relief valve with compressor oil.
2. Seat and O-ring must be clean and not damaged.
3. Install new high pressure relief valve.

Tightening Torque
b: 15 Nm (1.5 kg.m, 11.0 lb.ft)