Placing System In Operation

After component service or replacement has been completed and all connections have been made, thoroughly evacuate system with a vacuum pump. Charge system with proper amount of refrigerant and perform leak test. See REFRIGERANT OIL & REFRIGERANT SPECIFICATIONS article for system capacities. Ensure there are no leaks at any fitting that has been opened. After system has been leak tested, check system performance.