Compressor & Condenser Fan Relays
- Disconnect negative battery cable. Disconnect relay electrical connectors, and remove relay. Attach ohmmeter leads to relay terminals No. 3 and 4 Continuity should exist. If continuity does not exist, replace relay. Apply battery voltage to relay terminals No. 3 and 4. See Fig 1
.
- Attach ohmmeter leads to relay terminals No. 1 and 2. Continuity should exist with battery voltage applied. If continuity does not exist, replace relay.
Courtesy of SUZUKI OF AMERICA CORP.