LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Suzuki >> 1998 >> Sidekick JS, 4D Utility, Automatic >> Repair and Diagnosis >> Engine Performance >> System >> Engine Controls - System/Component Tests >> Engine Sensors & Switches >> Manifold Absolute Pressure (Map)/Manifold Differential Pressure (MDP) Sensor
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Manifold Absolute Pressure (Map)/Manifold Differential Pressure (MDP) Sensor

  1. To test MAP sensor on vehicle, turn ignition on. Connect scan tool to Data Link Connector (DLC). Connect a hand-held vacuum pump to MAP sensor. Observe scan tool display as specified vacuum is applied. See MAP SENSOR OUTPUT SIGNAL (ON-VEHICLE)  table.
  2. If scan tool reading is not within specification, see DTCs P0106, P0107 and P0108 (Esteem and Swift) or DTC P1408 (Sidekick and X-90) in TESTS W/CODES article. To bench test pressure sensor, see appropriate table below:

If voltage is not within specification, replace MAP sensor.

CAUTION: Damage to MAP sensor will occur if connections are made incorrectly.
MAP SENSOR OUTPUT SIGNAL (ON-VEHICLE) (1)

Vacuum (In. Hg) Scan Tool Display (kPa)
Esteem & Swift
0 100
8 73
20 33
(1) With scan tool installed, ignition on, and specified vacuum applied to MAP sensor.
MAP SENSOR OUTPUT VOLTAGE (OFF-VEHICLE) - ESTEEM & SWIFT

Altitude (Feet) Vacuum (In. Hg) (1)(2) Output Voltage
0-2000 28-30 3.1-3.6
2001-5000 25-28 2.8-3.4
5001-8000 22-25 2.6-3.1
8001-10,000 20-22 2.4-2.9
(1) MAP sensor output voltage is tested with three 1.5-volt batteries connected in series (output 4.5-5.0 volts). Positive battery lead is connected to "Vin" terminal. Negative lead is connected to "Ground" terminal. Check output voltage between "Vout" and "Ground" terminals. See Fig 1 .
(2) Voltage should reduce when up to 15 in. Hg of vacuum is applied to MAP sensor.
MAP SENSOR OUTPUT VOLTAGE (OFF-VEHICLE) - SIDEKICK & X-90

Vacuum (In. Hg) (1)(2) Output Voltage
8 2.4-4.4
10 2.1-4.1
12 1.9-3.9
14 1.6-3.6
16 1.3-3.3
(1) MAP sensor output voltage is tested with three 1.5-volt batteries connected in series (output 4.5-5.0 volts). Positive lead of batteries is connected to "Vin" terminal. Negative lead of batteries is connected to "Ground" terminal. Check output voltage between "Vout" and "Ground" terminals. See Fig 1 .
(2) Voltage should reduce when up to 15 in. Hg of vacuum is applied to MAP sensor.
Fig 1: Testing MAP Sensor
G96F09890Courtesy of SUZUKI OF AMERICA CORP.