Power Mirror Switch
Remove power mirror switch from instrument panel. Using an ohmmeter, check continuity between appropriate mirror switch terminals. See appropriate POWER MIRROR SWITCH CONTINUITY TEST . SeeFig 1 . If power mirror switch fails any test, replace power mirror switch assembly.
POWER MIRROR SWITCH CONTINUITY TEST (LEFT)
| Switch Position | Terminals No. |
|---|---|
| Up | 1 & 5; 2 & 3 |
| Down | 1 & 2; 3 & 5 |
| Left | 1 & 6; 2 & 3 |
| Right | 1 & 2; 3 & 6 |
POWER MIRROR SWITCH CONTINUITY TEST (RIGHT)
| Switch Position | Terminals No. |
|---|---|
| Up | 1 & 4; 2 & 3 |
| Down | 1 & 2; 3 & 4 |
| Left | 1 & 7; 2 & 3 |
| Right | 1 & 2; 3 & 7 |