DTC 15 - Abs Enable Relay Circuit Shorted To Battery Or Always Closed: Notes
NOTE:
For circuit and connector terminal identification, see WIRING DIAGRAMS
.
The EBCM engages pull-in coil of relay by completing the ground circuit at terminal No. 22 of the EBCM. This energizes relay windings, closing the internal contacts which supplies power to the motors and solenoids. DTC 15 can set only before the EBCM commands the ABS enable relay on.
NOTE:
Test numbers refer to test numbers on diagnostic chart.
- Indicates EBCM is capable of controlling the ABS enable relay as commanded.
- Checks for voltage at EBCM terminal "A". If voltage is present, malfunction exists in the ABS enable relay and/or its circuitry.
- Checks for a short to ground in the ABS enable relay control circuit.
- Checks for a short to voltage on circuit No. 6B01.
- Determines if the EBCM is malfunctioning.