Door Lock Key Cylinder Switch
Access appropriate power door lock key cylinder switch. Using an ohmmeter, check continuity between appropriate switch terminals. See DOOR LOCK KEY CYLINDER SWITCH CONTINUITY TEST . If power door lock switch fails any test, replace switch.
DOOR LOCK KEY CYLINDER SWITCH CONTINUITY TEST
| Switch Position | Terminals No. |
|---|---|
| Lock | 3 & 4 |
| Off | No Continuity |
| Unlock | 4 & 5 |