Operation Check
- Disconnect actuator connector and remove actuator cover. Carefully remove wire terminals No. 2 and 3 from actuator connector. See Figure
and Fig 1
.
Connect test leads between positive battery terminal and actuator terminals No. 2 and 3. Connect test leads between negative battery terminal and actuator terminals No. 1 and 4. SeeFig 2
. Actuator should operate to fully open position. After test is completed, carefully reinsert wire terminal back into connector.
Courtesy of SUZUKI OF AMERICA CORP.
Courtesy of SUZUKI OF AMERICA CORP.
- Carefully remove wire terminals No. 3 and 4 from actuator connector. Connect test leads between positive battery terminal and actuator terminals No. 3 and 4. Connect test leads between negative battery terminal and actuator terminals No. 1 and 2. SeeFig 3
. Actuator should operate to fully closed position. If actuator does not operate as described, replace actuator. After test is completed, carefully reinsert wire terminal back into connector.
Courtesy of SUZUKI OF AMERICA CORP.