Cooling System
COOLING SYSTEM SPECIFICATIONS
| Application |
Specification |
| Cooling System Capacity |
| Samurai |
5.1 Qts. (4.8L) |
| Sidekick 2-Door 8-Valve |
| A/T |
5.5 Qts. (5.2L) |
| M/T |
5.6 Qts. (5.3L) |
| Sidekick 4-Door 16-Valve |
| A/T |
5.3 Qts. (5.0L) |
| M/T |
5.4 Qts. (5.1L) |
| Swift |
4.9 Qts. (4.7L) |
| Pressure Cap |
| Samurai, Sidekick & Swift |
12.8 psi (.88 kg/cm2
) |
| Thermostat |
| Samurai |
| Thermostat Starts To Open |
| "A" Thermostat |
176.3-181.7°F (80.5-83.5°C) |
| "B" Thermostat |
187.3-192.7°F (86.5-89.5°C) |
| Thermostat Fully Opens |
| "A" Thermostat |
200.3-205.7°F (93.5-96.5°C) |
| "B" Thermostat |
| Sidekick |
| Thermostat Starts To Open |
176.3-181.7°F (80.5-83.5°C) |
| Thermostat Fully Opens |
200.3-205.7°F (93.5-96.5) |
| Swift DOHC |
| Thermostat Starts To Open |
174-184°F (79.2-84.8°C) |
| Thermostat Fully Opens |
198-208°F (92.2-97.8) |
| Swift SOHC |
| Thermostat Starts To Open |
185-195°F (85.2-90.8°C) |
| Thermostat Fully Opens |
207-217°F (97.2-102.8) |