A/C Diagnosis W/Gauges For SYS. W/Insufficient Or No Cooling

A/C DIAGNOSIS W/GAUGES FOR SYS. W/INSUFFICIENT OR NO COOLING

Low Side Gauge High Side Gauge Other Symptoms (1) Diagnosis
NORMAL NORMAL No or few bubbles in sight glass. High side gauge may go high. Low side gauge does not fluctuate with compressor on/off cycle. Some Air & Moisturein System
NORMAL NORMAL Cools okay in morning but not during hot part of day. Bubbles in sight glass. Discharge air warm when low side gauge drops into vacuum. Excessive Moisture in System
NORMAL NORMAL Thermostatic sw. sys. only- compressor cycles off & on too rapidly. Defective Thermostatic Sw.
NORMAL to HIGH NORMAL Cycling clutch sys only - compressor doesn't turn on soon enough. Discharge air becomes warm as low side pressure rises. Misadjusted Thermostatic Sw. orDefective Pressure Sensing Switch
LOW LOW Bubbles in sight glass. Outlet air slightly cool. Low R-12 Charge
LOW LOW Sight glass clear. Outlet air very warm. Excessively Low R-12 Charge
LOW LOW Outlet air slightly cool. Sweating or frost at expansion valve. Expansion Valve Stuck Closed Screen Plugged or Sensing Bulb Malfunction
LOW LOW Outlet air slightly cool. High side line cool to touch. Sweating or frost on high side. Restriction on High Side
LOW HIGH Evaporator outlet pipe cold. Low side goes into vacuum when blower is disconnected. STV Stuck Open
HIGH LOW Evaporator outlet pipe warm. Outlet air warm. STV Stuck Closed
HIGH LOW Noise from compressor. Compressor Malfunction
HIGH HIGH Outlet air warm. Liquid line very hot. Bubbles in sight glass. Compressor Malfunction or R-12 Overcharge
HIGH HIGH Outlet air slightly cool. Bubbles in sight glass. Large Amount of Air of Air & Moisture in System
HIGH HIGH Outlet air warm. Evaporator outlet sweating and frost. Expansion Valve Stuck Open
(1) If equipped with a low refrigerant charge protection system, compressor operation may have stopped.