Ignition Coil: Testing and Inspection
Checking Ignition Coil Resistance:
- Pull out high tension cord by gripping its cap.
- Disconnect ignition coil connector.
- Measure primary and secondary coil resistances.
PRIMARY RESISTANCE
0.9 - 1.1 ohms (at 20° C, 68° F)
SECONDARY RESISTANCE
10.2 - 13.8 Kohms (at 20° C, 68° F)