PANASONIC Rotary Vane Drain & Refill

  1. Before checking and adjusting oil level, operate compressor at 1000-1500 engine RPM, and set controls at maximum cooling and high blowing speed for about 10 minutes to return oil to compressor.
  2. Stop engine. Discharge refrigerant and remove compressor from vehicle. See SERVICING PRECAUTIONS at the beginning of this article. Drain oil from compressor through suction and discharge ports. Measure amount of oil drained. If amount drained is more than 2.4 ounces, fill with same amount using new oil. If amount drained is less than 2.4 ounces, fill with 2.4 ounces. Install compressor and recharge.
  3. If A/C components are replaced, add refrigerant oil to system. Add 1.4 ounces if condenser is replaced. Add 2 ounces if the evaporator is replaced. Oil does not need to be added if receiver-drier is replaced.