- Disconnect battery negative terminal. Disconnect relay electrical connectors and remove relays. Apply battery voltage to relay terminals No. 1 and 2. See Fig 1 .
- Attach ohmmeter leads to relay terminals No. 3 and 4. Continuity should be present with battery voltage applied. If continuity is not present, replace relay.