Sidekick & Swift
Disconnect thermistor electrical connector. Connect an ohmmeter to thermistor connector terminals. Ensure resistance is within specifications. See THERMISTOR RESISTANCE SPECIFICATIONS table. If continuity is not as specified, replace thermistor.
THERMISTOR RESISTANCE SPECIFICATIONS (1)
| Temperature | Ohms | ||
|---|---|---|---|
| 32°F (0°C) | 4500-5000 | ||
| 50°F (10°C) | 3000 | ||
| 70°F (20°C) | 1900 | ||
|
|||