Discharging A/C System
NOTE:
Recent findings by the EPA indicate that R-11, R-12 and R-113 are harmful to the Earths' protective Ozone layer. Make every attempt possible, to avoid discharging R-11, R-12 or R-113 into the atmosphere.
- Remove service valve caps and install gauges. For high side gauge hose, Adapter (D81L-19703-A) must be used to connect to high side service valve.
- Place open end of center hose in garage exhaust outlet or in a well ventilated area. Slightly open low side gauge valve and let refrigerant escape slowly without loosing refrigerant oil.
- When system is nearly discharged, using approved refrigerant recovery/recycling equipment, open high side gauge valve to release any pressure trapped in compressor. Close valves immediately after discharging to prevent entry of moisture.