Air Temperature Sensors

WARNING: This page is about a different car, the 2007 Suzuki XL7. However, it is still accessible from the selected car via links, so may be relevant.

The air temperature sensors are a 2-wire negative temperature co-efficient thermistor. The vehicle uses the following air temperature sensors:

A signal and low reference circuit enables the sensor to operate. As the air temperature surrounding the sensor increases, the sensor resistance decreases. The sensor signal voltage decreases as the resistance decreases. The sensor operates within a temperature range between -40 to +87.5°C (-40 to +190°F). The sensor signal varies between 0-5 volts.

The input of the duct air temperature sensors are different from the ambient and inside sensors. The HVAC control module converts the signal to a range between 0-255 counts. As the air temperature increases the count value will decrease.

If the HVAC control module detects a malfunctioning sensor, then the control module software will use a defaulted air temperature value. The default value for the inside air temperature sensor will be displayed on the scan tool. The default value for the duct air temperature sensors will not be displayed on the scan tool. The scan tool parameter for the duct air temperature sensors are the actual state of the signal circuit. The default action ensures that the HVAC system can adjust the inside air temperature near the desired temperature until the condition is corrected.

The ambient air temperature sensor mounts underhood and can be affected by city traffic, by idling, and by restarting a hot engine. Therefore, the HVAC control module filters the value of the ambient air temperature sensor for temperature display. The ambient air temperature value is updated under the following conditions:

HVAC CONTROL MODULE CONDITION TABLE

Condition Display
When the HVAC module A/C and RECIRCULATION buttons are pressed simultaneously. Updates temperature display instantly
At start up with the engine off less than 2 hours Displays last stored temperature unless temperature has decreased. The outside air temperature reading is always instantly updated if ambient air temperature has decreased.
At start up with the engine off more than 2 hours Displays actual outside temperature
Vehicle speed above 32 km/h (20 mph) for a minimum of 80 seconds Updates temperature display at a slow filtered rate
Sensor ambient temperature reading is less than the last displayed value Displays actual outside temperature
When the ambient air decreases. Updates temperature display rapidly