Starter - Direct Drive: Overhaul: Inspection: Brushes
Using a micrometer, measure brushes for wear. Standard measurement is .67" (17 mm). Minimum measurement is .45" (11.5 mm). If less than minimum, replace brushes.
Using a micrometer, measure brushes for wear. Standard measurement is .67" (17 mm). Minimum measurement is .45" (11.5 mm). If less than minimum, replace brushes.