Air Gap
- Using a flat, non-magnetic feeler gauge, check air gap between pick-up coil and reluctor. Air gap should be within .008-.016" (.20-.40 mm).
- If air gap is incorrect, remove ignition module and loosen screws securing pick-up coil. Move pick-up coil and adjust air gap to specification.