Electric Fluid Pump: Installation

  1. Install a new CVTF filter.
    NOTE:

    Perform only when the CVTF filter is removed. 

  2. Install a new O-ring.
    NOTE:

    Apply CVTF to the O-rings. 

  3. Install the electric oil pump, and connect the connector.

    Tightening torque: 

    22 N.m (2.2 kgf-m, 16.2 ft-lb)

  4. Install the electric oil pump cover and ground terminal.

    Tightening torque: 

    16 N.m (1.6 kgf-m, 11.8 ft-lb)

  5. Connect the ground terminal to battery sensor. Ref. to REPAIR CONTENTS>NOTE>BATTERY .
  6. Fill with CVTF. Ref. to CONTINUOUSLY VARIABLE TRANSMISSION (TR690)>CVTF>REPLACEMENT .