Combination Meter System: Inspection: Trouble Symptom
Illumination intensity does not change even when the illumination control switch is operated.
Wiring diagram:
Combination meter system Ref. to WIRING SYSTEM>COMBINATION METER SYSTEM>WIRING DIAGRAM
- CHECK DATA MONITOR
.
Using the Subaru Select Monitor, display the following items in the [Data monitor] of [Combination Meter]. Ref. to COMMON (DIAGNOSTICS)>DATA MONITOR
- [Bright switch input state]
- [Illumination control switch input state]
Do the display change as [OFF] ←→ [ON] and the value range from 0 to 100 when the bright switch and illumination control switch are operated?
Yes : Replace the combination meter assembly. Ref. to INSTRUMENTATION/DRIVER INFO>COMBINATION METER
No : Go to 2.
- CHECK ILLUMINATION CONTROL SWITCH UNIT
.
Check the illumination control switch. Ref. to INSTRUMENTATION/DRIVER INFO>SWITCHES AND HARNESS>INSPECTION>ILLUMINATION CONTROL SWITCH
Is the switch normal?
Yes : Go to 3.
No : Replace the illumination control switch. Ref. to INSTRUMENTATION/DRIVER INFO>SWITCHES AND HARNESS
- CHECK HARNESS
.
- Disconnect the connectors of combination meter assembly and illumination control switch.
- Measure the resistance between the combination meter assembly and the illumination control switch.
Connector & terminal
(i97) No. 29 - (i139) No. 6:
(i97) No. 30 - (i139) No. 5:
(i97) No. 31 - (i139) No. 4:
(i97) No. 32 - (i139) No. 1:
Is the resistance less than 1 Ω?
Yes : Replace the combination meter assembly. Ref. to INSTRUMENTATION/DRIVER INFO>COMBINATION METER
No : Repair or replace the defective part.