Main Switch
- Measure the resistance between terminals of the switch power window main.
Courtesy of SUBARU OF AMERICA, INC.
|
- Front seats auto specification
- Driver's seat main
| Terminal No. |
Inspection conditions |
Standard |
| 11 - 12 |
OFF |
Less than 1 Ω |
7 - 11 7 - 12 |
1 MΩ or more |
| 7 - 12 |
Manual UP |
Less than 1 Ω |
7 - 11 11 - 12 |
1 MΩ or more |
| 7 - 11 |
Manual DOWN |
Less than 1 Ω |
7 - 12 11 - 12 |
1 MΩ or more |
- Rear seat remote right (window lock OFF)
| Terminal No. |
Inspection conditions |
Standard |
1 - 7 2 - 7 |
OFF |
Less than 1 Ω |
| 7 - 16 |
1 MΩ or more |
1 - 16 2 - 7 |
Manual UP |
Less than 1 Ω |
| 1 - 2 |
1 MΩ or more |
2 - 16 1 - 7 |
Manual DOWN |
Less than 1 Ω |
| 1 - 2 |
1 MΩ or more |
- Rear seat remote right (window lock ON)
| Terminal No. |
Inspection conditions |
Standard |
| 1 - 2 |
OFF |
Less than 1 Ω |
| 7 - 16 |
1 MΩ or more |
| 1 - 16 |
Manual UP |
Less than 1 Ω |
1 - 2 2 - 7 |
1 MΩ or more |
| 2 - 16 |
Manual DOWN |
Less than 1 Ω |
1 - 2 1 - 7 |
1 MΩ or more |
- Rear seat remote left (window lock OFF)
| Terminal No. |
Inspection conditions |
Standard |
9 - 7 8 - 7 |
OFF |
Less than 1 Ω |
| 16 - 7 |
1 MΩ or more |
16 - 9 8 - 7 |
Manual UP |
Less than 1 Ω |
| 8 - 9 |
1 MΩ or more |
16 - 8 9 - 7 |
Manual DOWN |
Less than 1 Ω |
| 8 - 9 |
1 MΩ or more |
- Rear seat remote left (window lock ON)
| Terminal No. |
Inspection conditions |
Standard |
| 9 - 8 |
OFF |
Less than 1 Ω |
| 16 - 7 |
1 MΩ or more |
| 16 - 9 |
Manual UP |
Less than 1 Ω |
8 - 7 9 - 8 |
1 MΩ or more |
| 16 - 8 |
Manual DOWN |
Less than 1 Ω |
9 - 8 9 - 7 |
1 MΩ or more |
- All seats auto specification
- Driver's seat main
| Terminal No. |
Inspection conditions |
Standard |
| 12 - 11 |
OFF |
Less than 1 Ω |
7 - 11 7 - 12 |
1 MΩ or more |
| 12 - 7 |
Manual UP |
Less than 1 Ω |
7 - 11 12 - 11 |
1 MΩ or more |
| 11 - 7 |
Manual DOWN |
Less than 1 Ω |
7 - 12 11 - 12 |
1 MΩ or more |
- If the inspection result is not within the standard, replace the switch power window main.