Execution Condition
| Secondary parameters |
Execution condition |
| Battery voltage |
10.9 V or more |
| Rear oxygen sensor voltage when fuel cut starts |
More than 0.55V |
| (Elapsed time of fuel cut Fuel shut-off function thereafter) |
More than 5000ms Not in operation |
| Estimated temperature of rear oxygen sensor element when fuel cut starts |
500°C (932°F) or more |