September 30: LEMON manuals is back up on a temporary server! Slowness is possible
Check Relay
- Measure the resistance between relay terminals.
| TERMINAL NO. |
INSPECTION CONDITIONS |
STANDARD |
CIRCUIT |
| 1 - 2 |
Always |
1 MΩ or more |
|
| 1 - 4 |
Always |
Less than 1 Ω |
| 1 - 2 |
Apply battery voltage between terminals 3 and 5. |
Less than 1 Ω |
- Replace the relay if the inspection result is not within the standard value.