Unit Inspection
- Fuel pump check
- Resistance check
- Measure the resistance between the terminals.
| Inspection terminals |
Inspection conditions |
Standard value |
| 3 - 4 |
20°C {68°F} |
0.2 to 3.0 Ω |
- Operation check
- Apply the battery voltage between the terminals and check the motor operation.
CAUTION:
- Drain the fuel completely.
- Perform the check in a short period of time (10 sec. or less).
- Place the fuel pump as far apart as possible from the battery.
Courtesy of SUBARU OF AMERICA, INC.