October 30: LEMON manuals on a temporary server, it is slow and having issues, download the manuals you need! Later in November we will switch back to the fast server.
Map 2
TOTAL RETARD ANGLE AMOUNT SPECIFICATION
| ON/OFF |
Range |
Average of total retard angle amount (crank angle) |
| MT |
N |
19° |
| AT |
N |
19° |
| AT |
Other than N |
19° |
Time Needed for Diagnosis:
6 seconds
Malfunction Indicator Light Illumination:
Illuminates when malfunction occurs in 2 continuous driving cycles.