Inhibitor Switch: Installation
- Install inhibitor switch to transmission case. See Figure
.
- Move range select lever to neutral position.
- Using stopper pin, tighten bolts of inhibitor switch. See Figure
.
- Install select cable to range select lever.
- Install plate assembly to transmission. See Figure
.
- Install snap pin to range select lever. See Figure
.
- Install center exhaust pipe.
- Connect inhibitor switch connector. See Figure
.
- Install air intake chamber and duct.