LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Subaru >> 2001 >> Forester Base >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Air Conditioning System >> Service Procedure >> Performance Test >> Inspection >> Measurements
July 1: So it begins. Don't worry, this is not in the correct legal jurisdiction!

Performance Test: Inspection: Measurements

After 10 minutes (Minimum) of A/C operation and using accurate test equipment, take the following measurements (in order):

  1. Evaporator intake air temperature at recirculation door.
  2. Evaporator discharge air temperature at center grill.
  3. Condenser (Ambient) intake air temperature measured 0.9 m (3 ft) in front and in line with the center of the condenser
  4. Suction (Low) side pressure
  5. Discharge (High) side pressure
NOTE: If only one thermometer is available; 1) take the ambient measurement first; then 2) the intake air; and 3) discharge air temperature.