Oil Replacement
- After stabilization and discharge, replace the component, adding the appropriate amount of oil (ZXL200PG) to the new component before installation.
- If the compressor is replaced (after stabilization):
- Drain and measure the oil from the original compressor.
- Drain the oil from the replacement compressor and refill with the same amount that was drained from the original [20 ml (0.7 US fl oz, 0.7 Imp fl oz) minimum]. Always use ZXL200PG for the replacement oil.