  1. INSPECT SHIFT SOLENOID VALVE S1 
    1. Measure the resistance according to the value(s) in the table below.
      Fig 1: Identifying Shift Solenoid Valve S1
      GTY162230Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      TEXT IN ILLUSTRATION

      *a Component without harness connected
      (Shift Solenoid Valve S1)

      Standard Resistance

      Tester Connection Condition Specified Condition
      Solenoid Connector - Solenoid Body 15 to 25°C (59 to 77°F) 11 to 15 Ω

      If the value is not as specified, replace the shift solenoid valve.

    2. Connect a positive (+) battery lead to the terminal of the solenoid connector, and a negative (-) battery lead to the solenoid body, and check the operation of the valve.
      NOTE:

      When using battery voltage during this inspection, do not bring the positive and negative tester probes too close to each other as a short circuit may occur.

      OK

      The solenoid makes an operating sound.

      If the operation cannot be done as specified, replace the shift solenoid valve.

  2. INSPECT SHIFT SOLENOID VALVE S2 

    HINT: 

    For inspection procedure, refer to shift solenoid valve S1 above.

  3. INSPECT SHIFT SOLENOID VALVE ST 

    HINT: 

    For inspection procedure, refer to shift solenoid valve S1 above.

  4. INSPECT SHIFT SOLENOID VALVE SLT 
    1. Measure the resistance according to the value(s) in the table below.
      Fig 2: Identifying Shift Solenoid Valve SLT
      GTY164647Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      TEXT IN ILLUSTRATION

      *a Component without harness connected
      (Shift Solenoid Valve SLT)

      Standard Resistance

      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 5.0 to 5.6 Ω

      If the value is not as specified, replace the shift solenoid valve.

    2. Connect a positive (+) battery lead with a 21 W bulb to terminal 2 and a negative (-) battery lead to terminal 1 of the solenoid valve connector, and check the operation of the valve.
      NOTE:

      When using battery voltage during this inspection, do not bring the positive and negative tester probes too close to each other as a short circuit may occur.

      OK

      The solenoid makes an operating sound.

      If the operation cannot be done as specified, replace the shift solenoid valve.

  5. INSPECT SHIFT SOLENOID VALVE SLU 

    HINT: 

    For inspection procedure, refer to shift solenoid valve SLT above.