Valve Body Assembly: Inspection: Inspection
- INSPECT SHIFT SOLENOID VALVE S1
- Measure the resistance according to the value(s) in the table below.TEXT IN ILLUSTRATION
*a Component without harness connected
(Shift Solenoid Valve S1)Standard Resistance
Tester Connection Condition Specified Condition Solenoid Connector - Solenoid Body 15 to 25°C (59 to 77°F) 11 to 15 Ω If the value is not as specified, replace the shift solenoid valve.
- Connect a positive (+) battery lead to the terminal of the solenoid connector, and a negative (-) battery lead to the solenoid body, and check the operation of the valve.NOTE:
When using battery voltage during this inspection, do not bring the positive and negative tester probes too close to each other as a short circuit may occur.
OK
The solenoid makes an operating sound.
If the operation cannot be done as specified, replace the shift solenoid valve.
- Measure the resistance according to the value(s) in the table below.
- INSPECT SHIFT SOLENOID VALVE S2
HINT:
For inspection procedure, refer to shift solenoid valve S1 above.
- INSPECT SHIFT SOLENOID VALVE ST
HINT:
For inspection procedure, refer to shift solenoid valve S1 above.
- INSPECT SHIFT SOLENOID VALVE SLT
- Measure the resistance according to the value(s) in the table below.TEXT IN ILLUSTRATION
*a Component without harness connected
(Shift Solenoid Valve SLT)Standard Resistance
Tester Connection Condition Specified Condition 1 - 2 20°C (68°F) 5.0 to 5.6 Ω If the value is not as specified, replace the shift solenoid valve.
- Connect a positive (+) battery lead with a 21 W bulb to terminal 2 and a negative (-) battery lead to terminal 1 of the solenoid valve connector, and check the operation of the valve.NOTE:
When using battery voltage during this inspection, do not bring the positive and negative tester probes too close to each other as a short circuit may occur.
OK
The solenoid makes an operating sound.
If the operation cannot be done as specified, replace the shift solenoid valve.
- Measure the resistance according to the value(s) in the table below.
- INSPECT SHIFT SOLENOID VALVE SLU
HINT:
For inspection procedure, refer to shift solenoid valve SLT above.