LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Scion >> 2005 >> xB Standard >> Repair and Diagnosis >> General Information >> OEM General Information >> Service Specifications >> Cooling System >> Service Data
October 30: LEMON manuals on a temporary server, it is slow and having issues, download the manuals you need! Later in November we will switch back to the fast server.

Service Data

Cooling Service Data

Thermostat  
Valve opening temperature 80 to 84°C (176 to 183°F)
Valve lift at 95°C (205°F) 8.5 mm (0.335 in.) or more
Radiator cap sub-assy  
Standard opening pressure 93 to 123 kPa (0.95 to 1.25 kgf/cm2 , 13.5 to 17.8 psi)
Minimum opening pressure 78 kPa (0.8 kgf/cm2 , 11.3 psi)
Cooling fan  
Standard amperage 11.7 to 14.7 A
Cooling fan relay  
Resistance 3 - 5 10 kΩ or higher
3 - 5 (Apply battery voltage to terminals 1 and 2) Below 1 Ω
Cooling fan relay No. 2  
Resistance 3 - 4 Below 1 Ω
3 - 4 (Apply battery voltage to terminals 1 and 2) 10 kΩ or higher
3 - 5 10 kΩ or higher
3 - 5 (Apply battery voltage to terminals 1 and 2) Below 1 Ω
Cooling fan resistor  
Resistance at 20°C (68°F) 1.17 to 1.43 Ω