Electrical Specifications

Typical parasitic load for this vehicle is 10-15 mA. If vehicle does not have one of the following components, then subtract parasitic load of component for typical parasitic load of vehicle (10-15 mA) to determine parasitic load range for vehicle being tested.

^ ABS 1.0 mA
^ BCM 1.0-3.5 mA
^ CD Changer (refer to Note below) 3.0 mA
^ ECM 0-1.0 mA
^ Generator 0-1.0 mA
^ HVAC Delayed Blower Control 1.0 mA
^ I/P Cluster w/Security Flashing "Security" Telltale 1.2 mA
^ On-Star (refer to Note below) 0-1.0 mA
^ Radio 2.8-4.3 mA
^ TCM 0-10 mA