Diagnostic Procedure
- Using scan tool, read transmission oil temperature. If scan tool temperature reading is above -35°F (-37°C), problem is intermittent. Go to next step.
- Disconnect transmission oil temperature sensor connector. Sensor is between pressure filter and cooler line connection. Connect jumper wire between harness connector terminals. If scan tool reads greater than 284°F (140°C), possible poor connection exists or sensor is faulty. Using ohmmeter, inspect sensor and compare readings with TEMPERATURE SENSOR SPECIFICATIONS table. If scan tool reads 284°F (140°C) or less, go to next step.TEMPERATURE SENSOR SPECIFICATIONS
Temperature °F (°C) Ohms -40 (-40) 93630 -20 (-29) 46352 0 (-18) 24094 20 (-7) 13111 40 (4) 7436 60 (16) 4180 80 (27) 2554 100 (38) 1609 120 (49) 1043 140 (60) 693 160 (72) 456 180 (83) 318 200 (94) 226 220 (105) 165 248 (120) 109 284 (140) 65 - Connect jumper wire between ground and sensor harness connector terminal "A" (Orange/Black wire). If scan tool reads greater than 284°F (140°C), Black wire (terminal "B") is open or PCM is faulty. If scan tool reads 284°F (140°C) or less, Tan/White wire is open or PCM is faulty.