Acc Control Module Calibration

NOTE: ACC control module calibration is required when battery is disconnected or discharged, ACC control module or stepping motor has been replaced, or position of a flap has been changed.
  1. To calibrate ACC control module, turn ignition on. To start calibration, simultaneously press AUTO and OFF buttons on ACC control panel. Calibration and self-diagnostic test will end in approximately 30 seconds. Any DTCs detected during ACC control module calibration will be displayed on ACC display panel. See RETRIEVING DIAGNOSTIC TROUBLE CODES .
  2. The ACC control module will be automatically calibrated when ignition is turned on and ACC control module has been replaced. Automatic calibration will occur when ignition is turned on, after battery voltage to ACC control module terminal No. 22 (Red wire) has been cut, within 10 minutes of ignition being turned off.