September 30: LEMON manuals is back up on a temporary server! Slowness is possible
Ignition Output Control Signal
- Ensure DME control unit is properly connected. Connect oscilloscope positive lead to terminal No. 5 (White wire) and negative lead to terminal No. 2 (Brown wire) of the ignition control unit. See Figure
.
- Using ignition switch, operate starter motor. Oscilloscope must show DME control unit signal. See Figure
. If replacing ignition control unit, apply Heat Conducting Paste (5-942-860-003) to ignition control unit base plate.