HO2S 2
Scan Tool Range
0-1275 mV: The rear
HO2S 2 represents the exhaust oxygen output voltage beyond the
catalytic converter. This voltage will remain inactive or appear lazy within a range
100 mV (lean exhaust) and
900 mV (rich exhaust) when the system is operating in Closed Loop.