September 30: LEMON manuals is back up on a temporary server! Slowness is possible
EGR Closed Valve Pintle Position
Scan tool displays
0.0 to 5.0 volts. Represents the learned voltage that the PCM uses to determine whether or not the
EGR valve is fully closed (
0 percent pintle position). If the Desired
EGR Position is 0 percent and a difference of more than
0.4 volt between EGR Feedback and EGR Closed Valve Pintle Position is detected, DTC P1406 will set.