CHRYSLER Corp. Electronic Spark Control Distributor (Computer) Specifications

Application Rot.(1) A B C D E F G H I
409110(Dist.)  C                  
ESC Computer                    
4111373   5-11 10+5 0-2 1-4 0-3 8 11-15 18-22 6-10
4091140 (Dist.)  C                  
ESC Computer                    
  4111392   4-13 10+6 0-1 1-5 8-12 8 16-20 23-27 3-7
  4111439   4-12 10+6 2-6 6-10 1-3 8 8-12 18-22 6-10
  4111440   4-12 10+6 0-1 1-5 8-12 8 12-16 18-22 3-7
  4111441   4-12 12+0 3-7 8-12 6-10 8 11-17 18-22 0
  4111442   4-12 10+6 2-6 6-10 6-10 8 8-12 18-22 6-10
  4111492   4-13 10+6 0-1 1-5 8-12 8 16-20 23-27 3-7
  4111540   4-12 10+6 0-1 1-5 8-12 8 12-16 18-22 3-7
  4111574   4-13 10+6 0-1 1-5 0-3 8 16-20 23-27 3-7
  4111575   4-10 10+6 2-6 6-10 2-6 8 11-15 18-22 6-10
  4111650   4-12 10+6 0-1 1-5 18-22 8 12-16 18-22 3-7
  4111652   4-14 12+0 0-1 11-15 0-3 8 17-21 26-30 3-7
  4111656   4-14 12+0 3-7 8-12 18-22 0 13-17 18-22 0
  4111657   0-12 10+0 1-5 11-15 0-3 8 17-21 26-30 3-7
  4111674   4-13 10+6 0-1 1-5 0-3 8 16-22 23-27 3-7
  4111750   4-12 10+6 0-1 1-5 18-22 0 12-16 18-22 3-7
5206275 (Dist.)  C                  
ESC Computer                    
  5206721   0-10 10+5 0-3 8-12 6-10 8 18-22 23-27 0
  5206784   0-10 10+5 0-3 8-12 2-6 8 18-22 23-27 0
  5206785   0-10 10+5 0-3 8-12 3-7 8 18-22 28-32 0
  5206790   0-10 10+5 0-3 8-12 0-3 8 18-22 28-32 0
  5206793   0-10 10+0 0-3 8-12 0-3 8 18-22 23-27 0
A  - Vacuum Advance Range in In. Hg.
B  - Basic Timing Degrees (Crank Plus Electrical).
C  - Speed Advance Degrees at 1100 RPM.
D  - Speed Advance Degrees at 2000 RPM.
E  - Zero Time Offset in Degrees.
F  - Accumulator Clock Up Time in Minutes.
G  - Vacuum Advance Degrees at 1100 RPM (Full Acculumator).
H  - Vacuum Advance Degrees at 1500 RPM (Full Acculumator).
I  - Throttle Maximum Advance Degrees with Throttle Open 20°.
(1) C (Clockwise), CC (Counterclockwise) as viewed from rotor end.