Load Sensor

Position swing arm as shown in Fig. 3.  The target area must be positioned in front of threaded holes of bracket as shown. Using a depth gauge, measure distance "X" as shown in Fig. 3  . Distance "X" must be 1.138-1.146" (28.9-29.1 mm). If not, remove load sensor and adjust distance "X" using shims.

NOTE: Upper load sensor has a green ring on it or a green electrical connector and must be mounted in bracket hole with letter "V" stamped next to it.
Fig 1: EGR Load Sensor Adjustment
G09313990Courtesy of PEUGEOT MOTORS OF AMERICA, INC.