Work Procedure
- CHECK BATTERY TERMINALS CONNECTION
Check if battery terminals are clean and tight.
Is the inspection result normal?
YES>>
GO TO 2.
NO>>
Repair battery terminals connection.
- CHECK FUSE
Check for blown fuse and fusible link.
Unit Power source (Power supply terminals) Fuse No. Alternator Battery ("S" terminal) 32 Combination meter Ignition switch ON ("L" terminal) 3 Is the inspection result normal?
YES>>
GO TO 3.
NO>>
Replace the blown fuse after repairing the applicable circuit.
- CHECK "E" TERMINAL CONNECTION
Check if "E" terminal (alternator ground harness) is clean and tight.
Is the inspection result normal?
YES>>
GO TO 4.
NO>>
Repair "E" terminal connection.
- CHECK DRIVE BELT TENSION
Check drive belt tension. Refer to DRIVE BELT : Checking .
Is the inspection result normal?
YES>>
INSPECTION END
NO>>
Repair as needed.